NXP Semiconductors /MIMXRT1011 /ADC1 /GC

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as GC

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (ADACKEN_0)ADACKEN 0 (DMAEN_0)DMAEN 0 (ACREN_0)ACREN 0 (ACFGT_0)ACFGT 0 (ACFE_0)ACFE 0 (AVGE_0)AVGE 0 (ADCO_0)ADCO 0 (CAL)CAL

ACFGT=ACFGT_0, ACREN=ACREN_0, ADCO=ADCO_0, ACFE=ACFE_0, DMAEN=DMAEN_0, AVGE=AVGE_0, ADACKEN=ADACKEN_0

Description

General control register

Fields

ADACKEN

Asynchronous clock output enable

0 (ADACKEN_0): Asynchronous clock output disabled; Asynchronous clock only enabled if selected by ADICLK and a conversion is active.

1 (ADACKEN_1): Asynchronous clock and clock output enabled regardless of the state of the ADC

DMAEN

DMA Enable

0 (DMAEN_0): DMA disabled (default)

1 (DMAEN_1): DMA enabled

ACREN

Compare Function Range Enable

0 (ACREN_0): Range function disabled. Only the compare value 1 of ADC_CV register (CV1) is compared.

1 (ACREN_1): Range function enabled. Both compare values of ADC_CV registers (CV1 and CV2) are compared.

ACFGT

Compare Function Greater Than Enable

0 (ACFGT_0): Configures “Less Than Threshold, Outside Range Not Inclusive and Inside Range Not Inclusive” functionality based on the values placed in the ADC_CV register.

1 (ACFGT_1): Configures “Greater Than Or Equal To Threshold, Outside Range Inclusive and Inside Range Inclusive” functionality based on the values placed in the ADC_CV registers.

ACFE

Compare Function Enable

0 (ACFE_0): Compare function disabled

1 (ACFE_1): Compare function enabled

AVGE

Hardware average enable

0 (AVGE_0): Hardware average function disabled

1 (AVGE_1): Hardware average function enabled

ADCO

Continuous Conversion Enable

0 (ADCO_0): One conversion or one set of conversions if the hardware average function is enabled (AVGE=1) after initiating a conversion.

1 (ADCO_1): Continuous conversions or sets of conversions if the hardware average function is enabled (AVGE=1) after initiating a conversion.

CAL

Calibration

Links

() ()